About medication safety alerts

A practice manager can configure the routes and the safe dose ranges of a medication in SmartFlow settings. When staff enter a dose that is below the minimum or above the maximum, SmartFlow shows a warning.

Note: Medication safety alerts are only available for some customers at this time.

A medication in your SmartFlow settings can hold the limits that your practice agreed on for that medication. SmartFlow uses the limits to show alerts when staff prepare a medication treatment.

For each medication, a practice manager can configure:
  • The routes that staff can select
  • The route that SmartFlow selects automatically
  • A minimum dose and a maximum dose
  • A different minimum dose and maximum dose for a species or a route, or for the two together
  • Instructions for the medication
Table 1. Medication settings for safety alerts
SettingFunction
Acceptable routesThe routes that staff can select for the medication. If you do not add a route, staff can select all routes. SmartFlow selects the first route that you add automatically, and shows a star adjacent to it.
InstructionsSmartFlow shows the instructions to staff in the treatment settings of the medication and in the treatment task. The medication instructions are different from treatment instructions, which staff enter in a flowsheet.
Enable safety alertsTurns the dose warnings on or off for the medication.
Default safe rangeThe minimum dose and the maximum dose for all species and all routes.

Safety alerts

A safe dose range is a minimum dose and a maximum dose. You enter each value as a quantity for each kilogram of body weight (for example, mg/kg).

Note: If your organization uses pounds for the weight of patients, SmartFlow shows the same value for each pound below each box.

You can keep one of the two boxes empty.

The Default safe range is applicable to all species and all routes. A practice manager can also add a rule for:
  • One species (for example, dogs)
  • One route (for example, IV)
  • One species and one route (for example, dogs and IV)

To add these rules, the medication must have one or more routes in Acceptable routes. Each combination of species and route can have only one rule.

When Enable safety alerts is Off, you can add rules, and SmartFlow keeps the rules that you added.

Safety alerts in a flowsheet

When Enable safety alerts is On for a medication and staff enter a dose, SmartFlow compares the dose with the most applicable rule. SmartFlow uses the first applicable rule in this list:
  1. The rule for the species of the patient and the route of the treatment
  2. The rule for the species of the patient and all routes
  3. The rule for the route of the treatment and all species
  4. The Default safe range

SmartFlow compares the dose for each kilogram. If staff enter a dose for each pound, SmartFlow compares the same dose for each kilogram.

Table 2. Safety alert messages
MessageWhen SmartFlow shows it
Unusually low dose.The dose is less than the Warn if below value.
Unusually high dose.The dose is more than the Warn if above value.
Dosage within range.The dose is in the range.
No alerts set for this medication.No rule is applicable to the species of the patient and the route of the treatment.
CRI is not yet supported with Safety AlertsThe medication treatment is a CRI.
Safety Alerts do not support this dose unitThe dose is not a quantity for each unit of body weight (for example, a quantity for each animal).
Note: SmartFlow does not show a message until staff enter a dose.

Limitations

A warning does not prevent the treatment. Staff can save a treatment that has a dose below the minimum or above the maximum.

SmartFlow does not compare the dose of a CRI. SmartFlow also does not compare a dose that is not a quantity for each unit of body weight.

When Enable safety alerts is On, the concentration of the medication has a limit. You can select only a core measure and a core volume. Core measures and core volumes are the standard items that IDEXX adds to the lists of your organization, and you cannot remove them.